Default Battery System Voltage | 12V/24V/36V/48VDC (Auto detection) |
CONTROLLER INPUT |
PV Open Circuit Voltage | 100VDC@12V/ 145VDC @24V/ 145VDC @36V/ 145VDC @48V |
PV Array MPPT Voltage Range | 16VDC~100VDC / 32VDC~130VDC / 48VDC~130VDC / 64VDC~130VDC |
Max PV Input Power(12V) | 600W | 800W | 1050W |
Max PV Input Power(24V) | 1200W | 1600W | 2100W |
Max PV Input Power(36V) | 1800W | 2400W | 3150W |
Max PV Input Power(48V) | 2400W | 3200W | 4200W |
BATTERY |
Absorption Voltage | 12.5VDC/25.0VDC/37.5VDC/50.0VDC |
Refloat Voltage | 13.7VDC/27.4VDC/41.1VDC/54.8VDC |
Float Voltage | 14.3VDC/28.6VDC/42.9VDC/57.2VDC |
Low Voltage Protection Point | 10VDC/20VDC/30VDC/40VDC |
Temperature Compensation coefficient | -3mv/°C /cell (25°C vef) |
BATTERY |
Peak Conversion efficiency | 98% (MPPT Efficiency 99%) |
Max Charging Current | 45 amps continuous @ 40°C ambient | 60 amps continuous @ 40°C ambient | 80 amps continuous @ 40°C ambient |
GENERAL SPECIFICATION |
Radiating mode | Fan cooling |
DISPLAY & PROTECTION |
LED indication | Systematic operation, LV indication, LV protection, over charge protection, short circuit protection |
LCD display | Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output current |
Alarm Protections | PV array short circuit, PV reverse polarity;Battery reverse polarity, Over charging protection;Output short circuit protection;Low voltage protection for storage battery. |
MECHANICAL SPECIFICATIONS |
Mounting | Wall mount |
W*H* D(mm)/Net Weight(kg) | 167.6*257.1*82.9mm/3kg |
OTHER |
Environmental Rating | Indoor |
Operation Temperature Range | -25~55°C |
Ambient humidity | 0~90% relative humidity(non-condensing) |
Altitude | ≤3000m |
Loading(20GP/40GP/40HQ) | 3000pcs / 6000pcs / 7200pcs |